Leaking Hose Bib Repair in Orlando FL | CPVC Pipe Replacement & Stucco Restoration

Leaking Hose Bib Repair in Orlando, FL — CPVC Pipe Replacement & Stucco Restoration

Completed in early September 2025, this service call addressed a leaking hose bib that was saturating the exterior wall. After isolating the line at the main water shut-off, we performed a thorough inspection, confirmed internal failure at the spigot, and prepared for a full hose bib replacement with targeted CPVC pipe repair.

To protect the structure, we carefully opened the stucco, exposed the connection, and used professional tooling—pipe cutter, channel locks, and a CPVC deburring tool—to remove compromised components cleanly. We then solvent-welded new CPVC fittings using primer and solvent cement for a durable, leak-free bond.

We installed an anti-siphon frost-resistant hose bib to prevent backflow from irrigation and garden hoses, then pressure-tested the line to verify system integrity and optimal water pressure. Finally, we performed stucco patching and texture blending to restore the wall and keep moisture and pests out.

This project showcases best practices for outdoor spigot repair, including leak detection, CPVC solvent-welding, backflow protection, and exterior wall restoration—delivering a clean, code-compliant finish and long-term reliability.

Initial assessment of leaking hose bib at exterior wall in Orlando, FL, documenting drip and splash pattern

Initial Leak Assessment

Here I’m confirming the active leak at the hose bib, noting the drip rate and splash pattern against the stucco. I verify shut-off operation, check for CPVC hairline cracks, and rule out packing nut or vacuum breaker failures prior to spigot replacement.

Careful stucco opening to expose CPVC supply line and connection for hose bib replacement

Access & Preparation

With the water off, I open the stucco to expose the CPVC supply and union. Using a pipe cutter and deburring tool, I prepare square, clean pipe ends—critical for a strong primer and solvent cement bond and long-term leak prevention.

Installation of anti-siphon frost-resistant hose bib with freshly solvent-welded CPVC fittings

New Anti-Siphon Spigot

I install a frost-resistant anti-siphon hose bib and solvent-weld new CPVC fittings. This upgrade adds backflow protection, stabilizes water pressure, and eliminates the drip. We then pressure-test to confirm a tight, code-compliant seal.

Completed hose bib repair with stucco patch and texture blending for a seamless exterior finish

Wall Repair & Finish

With plumbing complete, I apply stucco patch, texture, and curing to seal the opening and match the façade. This prevents moisture intrusion, protects the sheathing, and completes a professional exterior spigot repair.